Vitex Pharmaceuticals Chiller Ventilation

PROJECT OVERVIEW

Vitex Pharmaceuticals Chiller

Passive Ventilation Designed for Industry-Grade Air Quality

Airocle supplied a natural ventilation system tailored to the specific environmental needs of Vitex Pharmaceuticals, enhancing internal airflow and air quality throughout their processing facility. The passive solution improves heat and moisture management while reducing reliance on mechanical ventilation, supporting a more comfortable and controlled workspace. As a result, the facility benefits from dependable, energy-free airflow that contributes to both operational efficiency and a healthier indoor environment.

  • LOCATION
    LOCATION
    Eastern Creek, NSW
  • INDUSTRY
    INDUSTRY
    Manufacturing
  • PRODUCT
    PRODUCT
    4 Series

KEY OUTCOMES

Project Highlights

Better Heat & Moisture Control

Consistent Conditions for Staff and Equipment

Passive ventilation reduces heat and humidity buildup, supporting both operator comfort and the performance of temperature-sensitive machinery.

Energy-Free Ventilation

Low-Maintenance, Cost-Efficient Operation

With no mechanical components or power demand, the system delivers reliable airflow while minimising operational costs and ongoing maintenance requirements.

Improved Air Quality

Cleaner Conditions for Pharmaceutical Production

The natural ventilation system enhances internal airflow, helping maintain fresher, more stable air conditions within high-sensitivity processing areas.

The Challenge

Vitex Pharmaceuticals, situated in the bustling region of Eastern Creek in Southwest Sydney, sought a solution for its chiller ventilation requirements. The facility’s chillers, crucial for maintaining pharmaceutical products’ optimal temperatures, faced a significant challenge – the chiller units were overheating due to the heat recirculating and not escaping. The issue not only impacted the efficiency of the chillers but also posed potential risks to the integrity of the stored pharmaceuticals. 

 

The Solution

To address this complex challenge, Vitex Pharmaceuticals turned to Airocle for an effective solution. Recognising the importance of a comprehensive approach, Airocle conducted a Computational Fluid Dynamics (CFD) analysis of the site. This involved mapping the temperature contours and velocity vectors to gain a comprehensive understanding of the airflow dynamics and temperature differentials within the facility. 

Airocle’s team then presented an executive summary to Vitex Pharmaceuticals, outlining the potential benefits of installing natural ventilation systems. The summary included a detailed analysis of the projected temperature differentials post-ventilation installation, along with a comprehensive estimation of the long-term return on investment. 

After careful consideration, Vitex Pharmaceuticals chose to implement the solution by installing 9 x Airocle 4SV.2030 4 Series Ventilators strategically throughout their facility. 

The Results

With Airocle’s solution in place, the temperature differential has been maintained at an impressive 0-4 degrees Celsius, significantly improving indoor climate control and minimising condensation-related challenges. This outcome stood in stark contrast to the temperature differences of 5 to 8 degrees Celsius experienced before the installation. This accomplishment was particularly remarkable, considering temperature differential figures were based on a scorching 40-degree Celsius day, which marks a comparable difference.  

Airocle’s long-term analysis also estimated the substantial benefits that Vitex Pharmaceuticals would accrue over a decade. It was projected that the natural ventilation installation will lead to savings of approximately $513,000 over the course of 10 years. This financial gain is projected to be a direct result of improved chiller efficiency, reduced risk to pharmaceutical integrity, and enhanced energy conservation. 

The collaboration between Vitex Pharmaceuticals and Airocle exemplifies the transformative impact of innovative ventilation solutions. By addressing complex temperature differentials and optimising chiller efficiency, Airocle 4 Series Ventilators not only enhanced operational performance but also contributed significantly to cost savings and overall sustainability, underscoring the effectiveness of tailored solutions in industrial settings. 

Product Enquiry

We are ISO certified. Our systems, processes, and procedures meet strict international standards, reassuring you of service excellence, quality, and consistency of our services and products no matter where you are located.